Assessment of Steel Structure Connections After Fire Exposure Through Bolt Torque Testing and Dye Penetrant Inspection

Authors

  • Zel Citra Universitas Mercu Buana
  • Antonius Antonius Universitas Islam Sultan Agung
  • Agung Wahyudi Biantoro Universitas Mercu Buana

DOI:

https://doi.org/10.61132/iconfes.v2i1.41

Keywords:

Bolt Torque Test, Dye Penetrant Test, Non-Destructive Test, Post Fire, Steel Structure

Abstract

In 2022, a significant fire incident occurred at a steel tower structure in an industrial plant in Lampung, Indonesia, raising serious concerns about the structural integrity and serviceability of the affected steel framework. Fire exposure is known to alter the properties of steel, weaken bolt pretension, and cause defects in welds, underscoring the necessity of thorough post-fire assessments. Nondestructive testing (NDT) methods are crucial in evaluating the safety and stability of structures after fire exposure, as they can detect potential weaknesses without compromising the material further. This study employed two field inspection methods: the bolt torque test and dye penetrant inspection (DPI). A total of 21 bolts (Tor-1 to Tor-21) were tested for their integrity. The results showed that, while all bolts were present, more than half were found to be loosened, indicating the need for re-tightening to restore the specified torque and maintain the required preload for the bolted connections. In addition, 20 welded joints (DP-1 to DP-20) were examined using DPI to detect surface defects. The inspection revealed that 10 welds (50%) exhibited surface defects exceeding 5 mm in length, indicating areas where the welds had been compromised by the fire exposure. Seven welds (35%) were found to be in acceptable condition, while 2 welds (10%) were incomplete or had poor bonding. These findings suggest that while the bolted joints can be restored through corrective re-tightening, the welded joints require more extensive evaluation, local repairs, or even rewelding to ensure their structural integrity. This study highlights the importance of NDT methods in post-fire structural evaluations and recommends periodic inspections and targeted rehabilitation to ensure the long-term reliability and safety of industrial steel structures.

References

Ali, F., O’Connor, D., & Abu-Tair, A. I. (2001). Structural performance of bolted connections in fire. Journal of Constructional Steel Research, 57(12), 1159–1173. Oxford: Elsevier. https://doi.org/10.1016/S0143-974X(01)00031-7

ASTM. (2018). ASTM E165/E165M-18: Standard practice for liquid penetrant examination for general industry. West Conshohocken, PA: ASTM International.

Bisby, L. A., Kodur, V. K. R., & Green, M. F. (2005). Performance of fire-exposed steel structures: A state-of-the-art review. Progress in Structural Engineering and Materials, 7(2), 94–103. Chichester: Wiley. https://doi.org/10.1002/pse.201

Chen, X., Li, H., & Zhou, Y. (2024). High-temperature behavior of welded steel joints: Experimental and numerical investigations. Journal of Constructional Steel Research, 205, 107907. Elsevier. https://doi.org/10.1016/j.jcsr.2023.107907

Cirpici, B. K., & Sagiroglu, S. (2024). Experimental study on post-fire performance of welded steel connections. Engineering Structures, 305, 115720. Elsevier. https://doi.org/10.1016/j.engstruct.2023.115720

Haiko, T., Outinen, J., & Mäkeläinen, P. (2021). Mechanical properties of structural steels subjected to fire and different cooling regimes. Fire and Materials, 45(2), 191–205. Wiley. https://doi.org/10.1002/fam.3012

Hawkins, N. (2022). Numerical analysis of bolted connections under fire conditions. Journal of Structural Fire Engineering, 13(4), 377–390. Emerald. https://doi.org/10.1108/JSFE-01-2022-0002

ISO. (2013). ISO 3452-1:2013 Non-destructive testing — Penetrant testing — Part 1: General principles. Geneva: International Organization for Standardization.

Kiran, R., & Kodur, V. K. R. (2019). Post-fire evaluation of steel structures using nondestructive testing techniques. Fire Technology, 55(6), 2205–2224. New York: Springer. https://doi.org/10.1007/s10694-019-00863-4

Lou, G., Wang, Y., & Sun, R. (2017). Thermo-mechanical modeling of steel structures after fire exposure. Fire Safety Journal, 91, 738–750. Elsevier. https://doi.org/10.1016/j.firesaf.2017.04.006

Maraveas, C., Tsavdaridis, K. D., & Efthymiou, E. (2017). Residual strength of fire-exposed structural steel: A comprehensive review. Journal of Constructional Steel Research, 138, 62–82. Elsevier. https://doi.org/10.1016/j.jcsr.2017.07.019

Silva, V. P., & Rodrigues, J. P. C. (2020). Residual mechanical properties of structural steels after fire: A review. Fire Safety Journal, 111, 102941. Amsterdam: Elsevier. https://doi.org/10.1016/j.firesaf.2019.102941

SNI. (2017). SNI 8458:2017 – Metode pengencangan baut untuk konstruksi baja. Jakarta: Badan Standardisasi Nasional.

Steel Institute of Australia. (2020). Post-fire assessment of steel structures. Sydney: Steel Institute of Australia.

Yu, W., Zhang, L., & Chen, S. (2019). Thermal response and residual strength of bolted steel connections under elevated temperature. Engineering Structures, 196, 109317. Elsevier. https://doi.org/10.1016/j.engstruct.2019.109317

Zhang, L., Yu, W., & Chen, S. (2023). Influence of fire exposure and cooling regimes on the mechanical performance of high-strength bolts. Journal of Structural Engineering, 149(5), 04023043. ASCE. https://doi.org/10.1061/(ASCE)ST.1943-541X.0003434

Downloads

Published

2025-01-30

How to Cite

Citra, Z., Antonius Antonius, & Biantoro, A. W. (2025). Assessment of Steel Structure Connections After Fire Exposure Through Bolt Torque Testing and Dye Penetrant Inspection. Proceeding of the International Conferences on Engineering Sciences, 2(1), 61–71. https://doi.org/10.61132/iconfes.v2i1.41